Biomechanical Analysis
Methods and data collection
One physically active participant completed the testing procedure. The participant performed three countermovement jumps (no arm swing) at each of the three target knee flexion angles.
• ~45̊ knee flexion
• ~90̊ Knee flexion
• ~90+̊ Knee flexion
The participant aimed to achieve knee flexion angles as close as possible to the designated ranges during each jump. All jumps were performed with maximal effort to achieve maximum vertical jump height.
Testing was conducted indoors on a basketball court with a flat surface to ensure consistency between all jumps. There was a one minute plus break between each jump allowing for adequate rest to minimize effects of fatigue on jump performance.
Each jump was recorded using an iPhone camera and a Nikon D5500 camera. The iPhone footage was recorded through the My Jump Lab app which was further utilized to calculate maximal vertical jump height and impulse through built in flight-time analysis. The Nikon D5500 camera footage was recorded on a tripod from a sagittal plane view to allow for detailed biomechanical analysis using Kinovea motion analysis software.
Kinovea was used to analyze knee flexion angle at the lowest point of the countermovement phase. Anatomical landmarks at the hip, knee, and ankle joints were visually identified to calculate knee joint angles during each jump trial.
The primary quantitative variables collected throughout testing included:
• Knee flexion angle
• Maximal vertical jump height
• Impulse
In addition to these quantitative measurements, qualitative observations relating to movement technique, movement efficiency, and jump mechanics were analyzed through video footage.
To ensure testing reliability, camera position, jump surface, hands on hips, and testing instructions remained consistent across all jumps.
Jumps with knees at 45 degrees angle
Jumps with knees at 90 degrees angle
Jumps with knees at 90+ degrees angle
IMAGE SEQUENCES
JUMP 3
Biomechanical Analysis
![]() |
| Table 1. Presents the My Jump App Data and Results Across Knee Flexion Conditions |
One of the primary biomechanical principles explaining the results is impulse, which is defined as the product of force and the time over which force is applied. The data (Figure 2) showed that increasing knee flexion from around 45̊ to 90̊ resulted in a 15.2% increase in average impulse, from 180.76N-s to 208.15N-s. Alongside the impulse the average jump height also increased from 28.1cm to 37.25cm, an additional 32.6%. These findings suggest that the greater countermovement depth allowed force to be applied over a longer period of time, increasing the total impulse generated during the concentric phase of the jump. However, knee flexion that went beyond 90̊ did not result in any meaningful change in impulse, remaining almost identical at 208.20N-s. Jump height also remined largely unchanged at 37.32cm. This indicates that while increasing knee flexion from a shallow position improves impulse generation and jump performance, further increases in knee flexion did not provide meaningful additional performance benefits. Therefore, using impulse as a biomechanical principle helps support the hypothesis that knee flexion angle around 90 to 100 degrees provides an optimal balance between force production and movement efficiency, resulting in greater vertical jump performance.
| Figure 2. Average impulse by knee flexion angle during the countermovement jump |
The second biomechanical principle is the stretch-shortening cycle (SSC). SSC has 3 phases. The first phase is the eccentric phase or the stretch; this phase the muscle stretches creating tension. This is when the knees are bent. This can look like a slingshot being stretched back with the point of tension in the knees, hips and ankles. The next phase is the amortization phase or the transition phase. This phase is the momentary pause between stretch and the shortening. To achieve max power in this phase, this action needs to be as short and explosive as possible. The third and final phase is the concentric phase or the shortening phase. In this phase the muscles shorten and contracts, releasing all the built-up energy, force and power in one explosive movement ableing the body to jump upwards into the air.
| 45 Degree Angle Jump 1 |
Basing off the biomechanical principle of SCC, when the
angle is in and around the 90s, forcing the knee muscles to stretch in the
eccentric phase, can allow for a bigger explosive reaction to push the body
into the air higher than what a greater angle allows the athlete to do. Data
from table 1 shows that when the athlete jumped at the 90 degree angle, they
got an average of 37.25cm jumping height compared to the first 3 jumps of
28.1cm jumping height. Flight time also increased by an average of 72.5ms. 45
degree jumping angles on average; 478.61ms in flight time vs 90 degree angles
on average; 551.11ms. In the 90+ degree angles the jumping data sets remained
relatively similar which can indicate during the amortization phase the
explosive reaction taking too long to complete which that inefficiency doesn’t
allow the athlete to achieve a higher jump.
| 45 Degree Angle |
| 90 Degree Angle |
| 90+ Degree Angle |
As the biomechanical principle of triple flexion suggests, when an athlete coordinates simultaneous movement from ankle plantar flexors, knee extensors and hip extensors accompanied by applied force, the muscles and lower joints act like springs to propel the body upward. These actions are shown in all 3 jump tests. Data in table 2 shows the impulse results and when jumping at a 90-90+ degree angle proves to be best compared to jumping at a 45 degree angle. Jumping at the 45 degree angle can greatly impact the creation of force and coordinated movements of the lower joints; the knee extensors work harder than other joints which hinder the simultaneous movement creating lower data scores.
1st 90 degree jump 1st 90+ degree jump
Another important biomechanical factor influencing the results is the interaction between joint angles, particularly at the knee and hip. Although this investigation focused primarily on knee flexion angle, the image sequences showed that the 90+° condition involved noticeably greater hip flexion and a lower centre of mass compared to the 45° and 90° conditions. Lowering the centre of mass during the eccentric phase may increase the range of motion and distance over which force can be applied during the upward propulsion phase. In theory, this could increase force production by allowing greater contribution from the hip extensors as part of the triple extension movement pattern. However, the results showed that the 90+° condition did not produce a meaningful increase in jump height compared to the 90° condition. This suggests that the additional hip flexion and lowering of the centre of mass did not translate into greater vertical propulsion. Instead, the deeper position may have increased movement duration and reduced mechanical efficiency, meaning the participant had to travel through a larger range of motion without gaining a substantial performance benefit. Therefore, the findings indicate that optimal countermovement jump performance depends not only on knee flexion angle, but also on how effectively the hip, knee, and ankle interact to position the body for efficient force production and take-off.
PRACTICAL FINDINGS
The findings from this investigation supported our hypothesis that a knee flexion angle between 90-100 can provide the highest countermovement (no arm swing) jump height results. The analysis described how key biomechanic principles such as impulse and SSC were affected by knee flexion angle and supported higher countermovement jump heights.











Comments